PRODUCT OVERVIEW
Advantech GeniDAQ is an intuitive Windows-based
graphic application builder that is designed for supervising and visualization of machines
and small plants. Advantech GeniDAQ provides a common development tool for different size
HMI platforms. From 5.7" inch HMI to 15" inch HMI, Windows NT, Windows 98/95 to
Windows CE, single machine to multiple station systems, you just need one tool to
configure your front panel. It also features multi-threaded engine for optimal
performance, open architecture for integrating your solution, and standard OPC (OLE for
Process Control) driver interface to connecting your existing devices. Advantech GeniDAQ 4.1 includes the following new
features: Advantech GeniDAQ takes maximum advantage of Windows' multi-tasking capabilities to
enhance your system performance. It speeds up the task scanning by separating
time-consuming display drawing from I/O scanning and raising the scan priority of task, no
matter how complex your display is. In addition, it provides parallel scan for each task.
It results in more efficient task scan for independent I/O, such as COM port devices with
long response time. Moreover, because of independent task scanning, it will not affect the
system safety if one task is failed. You can also prioritize your tasks to meet
time-critical operation and optimize your system performance. Finally, as multitasking
design, it will not block off the task scanning or display update at operating your user
interface, such as holding on the window. All of these provide you the industrial secure
and real-time environment for your applications. In your plant or system, there may already exist some devices, instead of Advantech
I/O. Advantech GeniDAQ leverages the industry OPC standard to provide the plug-and-play
connectivity with your devices, such as programmable logic controllers (PLCs). Most of
major PLC vendors provide the OPC servers for their hardware. GeniDAQ seamlessly
integrates OPC client function in I/O blocks. It allows you to browse the pre-defined tags
in OPC server, and you only need to click on the item that you want to access. Advantech GeniDAQ's networking capability allows a computer in the control room to
display data being collected by computers on the factory floor, or vice versa. This means
that data and field process can be viewed or monitored in real time from anywhere on your
network. GeniDAQ implements a network system that supports peer-to-peer communication
using TCP/IP protocol. It allows networking status to log and view for networking
monitoring and maintenance. Besides, it also provides browsing function to configure
remote tags for network input block. Advantech GeniDAQ allows you to build your front panel interface for different size
HMI (Human Machine Interface) platforms from size of 5.7" to 15" inch. You can
develop your application on Windows NT or Windows98/95, then run it on these operating
systems or Windows CE. With GeniDAQ, you don't have to buy and learn different application
software package for different models. It significantly reduces your development effort
and cost. Advantech GeniDAQ is based the 32-bit DLL driver to support Advantech data
acquisition and control hardware. Now GeniDAQ supports Advantech PCI-bus data acquisition
and control cards. You can also use our OPC servers to link ADAM-5000/CAN I/O modules and
ADAM-5511 controller. Advantech GeniDAQ now can support up to 99 historical trending display objects.
Historical trending display object also allows you to go to a specific time and search for
a specific value. Other enhancement includes the automatic scrolling at starting running,
button tooltip for easy operation, and more intuitive historical data conversion. Advantech GeniDAQ now supports String, Long, and Floating point data type for
virtual tag. It is more flexible to use the virtual tag to keep your data. It allows you
to create customized tags and store them in data center, then share them with different
tasks. In the past, GeniDAQ provides save and restore function for control objects,
including knob, numeric control, slider, button and conditional button. Now this function
also supports analog output and digital output block. It allows you to save the output
values at system stopping. And restore the values to initialize the hardware at next
system running. Advantech GeniDAQ now provides security protection for your strategy file. You can
distribute your application with safety. Advantech GeniDAQ provides a lot of user interface enhancement, including
scrollable display windows for large display, dockable toolbox to customize your working
style, new menu bar icons to configure more quickly, and icon tooltip for easy operation.
The user interface enhancement increases your productivity. Advantech GeniDAQ now allows you to port the device configuration from one machine
to another machine. It saves your time to reconfigure the devices on another machine.
First you export the device configuration from Registry to a *.reg file on one machine.
Then import the device configuration from the *.reg file to Registry on another machine. Advantech GeniDAQ now utilizes project concept to design your strategies. It allows
you to manage and maintain your project more easily. GeniDAQ creates a new directory when
you create a new strategy. All files including strategy file, historical data files,
exported device configuration file (*.reg), and log files exist in the directory. Advantech GeniDAQ adds a few new Basic Script commands, including data lock
function for multi-threaded protection, overrun message disabling, and querying network
status function.
Advantech GeniDAQ adds a new task block, system control
block. It allows user to control task and system operation, and to switch display by
program.
Advantech GeniDAQ adds a new display object, event log window display. It allows user to create resizable event log window.
Advantech GeniDAQ includes two OPC server, serial Modbus RTU OPC server and ADAM OPC server.
COMPATIBILITY AND UPGRADE INFORMATION
This version allows users to load the old strategy files and save them into the new format. However, since this version supports multi-tasking operating system that is very different from the previous one, it can not guarantee that the previous strategy file will run normally in this version, especially for the strategies with multiple tasks. Also this version removes the function blocks, including user programming block, user-defined DLL icon, network output block, and report designer. After you save the old strategy files into the new format, these blocks or functions will be discarded.